Inter-examiner reliability of infrared thermography for the diagnosis of complex regional pain syndrome.
Eunjoo Choi
Pyung-Bok Lee
Francis Sahngun Nahm
Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
ABSTRACT BACKGROUND/PURPOSE: Infrared thermography (IRT) is a useful tool for assessing skin temperature abnormalities in patients with complex regional pain syndrome (CRPS). Although determining regions of interest (ROIs) is an essential process for interpreting thermographic images, there are no validated and standardized guidelines to determine ROIs. Therefore, ROIs may be determined differently by each observer even for the same IRT images, which can result in an important issue for IRT reliability. The purpose of this study was to investigate the inter-examiner reliability of IRT in patients with CRPS.
METHODS: Infrared thermographic images of 28 patients diagnosed with CRPS were reviewed by three independent examiners. The shapes, sizes, and the detailed locations of the ROIs were determined by the investigator's own opinion based on patient history and symptoms. After maximal skin temperature of the ROI was obtained for each patient, the degree of agreement among the three examiners limbs was assessed.
RESULTS: The intraclass correlation coefficient among the three independent raters was 0.865 (95% confidence interval, 0.748-0.933), indicating a high degree of reliability (P < 0.001).
CONCLUSIONS: The reliability of IRT for assessing skin temperature abnormalities in CRPS was high when the ROIs were determined based on patient history and symptoms.
Showing posts with label infrared. Show all posts
Showing posts with label infrared. Show all posts
Thursday, June 16, 2016
Monday, June 13, 2016
Appearance of human meridian-like structure and acupoints and its time correlation by infrared thermal imaging.
Appearance of human meridian-like structure and acupoints and its time correlation by infrared thermal imaging.
Yang HQ, Xie SS, Hu XL, Chen L, Li H. Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education, Institute of Laser and OptoElectronics Technology, Fujian Normal University, Fuzhou 350007, China.
"The meridians and acupoints of human bodies at natural condition are investigated among 30 healthy volunteers by infrared thermal imaging technique. The results give clear evidence of the existence of infrared radiant tracks along human meridian courses. The time dependent evolution of the infrared radiant track is observed for the first time. The time rhythm of acupoints is also studied. Our findings not only support the view that infrared radiant tracks along human meridian courses is a normal vital and physiological phenomenon appearing in human beings, but also offer a potential method for noninvasive diagnostic by studying the physiological function and pathological change of meridians or acupoints by means of thermography."
Yang HQ, Xie SS, Hu XL, Chen L, Li H. Key Laboratory of OptoElectronic Science and Technology for Medicine of Ministry of Education, Institute of Laser and OptoElectronics Technology, Fujian Normal University, Fuzhou 350007, China.
"The meridians and acupoints of human bodies at natural condition are investigated among 30 healthy volunteers by infrared thermal imaging technique. The results give clear evidence of the existence of infrared radiant tracks along human meridian courses. The time dependent evolution of the infrared radiant track is observed for the first time. The time rhythm of acupoints is also studied. Our findings not only support the view that infrared radiant tracks along human meridian courses is a normal vital and physiological phenomenon appearing in human beings, but also offer a potential method for noninvasive diagnostic by studying the physiological function and pathological change of meridians or acupoints by means of thermography."
Thursday, June 9, 2016
Isotope perfusion and infrared thermography of arterialised, venous flow-through and pedicled venous flaps.
Isotope perfusion and infrared thermography of arterialised, venous flow-through and pedicled venous flaps.
Wolff KD, Telzrow T, Rudolph KH, Franke J, Wartenberg E. Source Department of Maxillofacial Plastic Surgery, Steglitz Medical Center, Free University of Berlin, Germany.
Abstract
In an experimental study on the epigastric venous system of rats, we examined three types of venous flaps with regard to their perfusion and long-term results: arterialised venous flaps, flow-through venous flaps and venous island flaps. We documented afferent and efferent blood flow with radiolabelled substances and blood distribution with infrared thermography. By measuring the surviving flap surfaces after 4 months, the relative success rate for each flap type was determined. The results show that in the chosen model the entire surface of the arterialised venous flap had a survival rate of 92.7%, the flow-through venous flap 62.4%, and the venous island flap about 31%. The venous island flaps had the worst distribution of intravenously injected 125J-Fibrinogen, and it was significantly worse in all types of venous flaps than in standard epigastric flaps; moreover, the clearance of intracutaneously injected 99mTc was the lowest in venous island flaps. The infrared thermographic study showed that the blood in the arterialised venous flaps dispersed faster and over a larger area than in flow-through venous and island flaps. Given these results, we conclude that arterialised venous flaps are the safest form of venous flaps, whereas venous island flaps carry a high risk of partial or total necrosis.
Wolff KD, Telzrow T, Rudolph KH, Franke J, Wartenberg E. Source Department of Maxillofacial Plastic Surgery, Steglitz Medical Center, Free University of Berlin, Germany.
Abstract
In an experimental study on the epigastric venous system of rats, we examined three types of venous flaps with regard to their perfusion and long-term results: arterialised venous flaps, flow-through venous flaps and venous island flaps. We documented afferent and efferent blood flow with radiolabelled substances and blood distribution with infrared thermography. By measuring the surviving flap surfaces after 4 months, the relative success rate for each flap type was determined. The results show that in the chosen model the entire surface of the arterialised venous flap had a survival rate of 92.7%, the flow-through venous flap 62.4%, and the venous island flap about 31%. The venous island flaps had the worst distribution of intravenously injected 125J-Fibrinogen, and it was significantly worse in all types of venous flaps than in standard epigastric flaps; moreover, the clearance of intracutaneously injected 99mTc was the lowest in venous island flaps. The infrared thermographic study showed that the blood in the arterialised venous flaps dispersed faster and over a larger area than in flow-through venous and island flaps. Given these results, we conclude that arterialised venous flaps are the safest form of venous flaps, whereas venous island flaps carry a high risk of partial or total necrosis.
Wednesday, June 8, 2016
Infrared thermography: Experience from a decade of pediatric imaging.
Infrared thermography: Experience from a decade of pediatric imaging.
Saxena AK, Willital GH. Department of Pediatric Surgery, Medical University of Graz, Auenbruggerplatz 34, Graz, A-8036, Austria
The aim of this study was to evaluate the feasibility of clinical application of infrared thermography (IRT) in the pediatric population and to identify pathological states that can be diagnosed as well as followed up using this non-invasive technique. In real time computer-assisted IRT, 483 examinations were performed over a period of 10 years from 1990-2000 on 285 patients in the pediatric age group (range 1 week-16 years) presenting with a wide range of pathologies. The temperature was measured in centigrade (degrees C), and color images obtained were computer analyzed and stored on floppy discs. IRT was found to be an excellent noninvasive tool in the follow-up of hemangiomas, vascular
malformations and digit amputations related to re implantation, burns as well as skin and vascular
growth after bio-material implants in newborns with gastroschisis and giant omphaloceles. In the
emergency room, it was a valuable tool for rapid diagnosis of extremity thrombosis, varicoceles,
inflammation, abscesses, gangrene and wound infections. In conclusion, IRT can be performed in
the pediatric age group, is non-invasive, without any biological side effects, requires no sedation or
anesthesia and can be repeated as desired for follow-ups, with objective results that can demonstrated as colored images. Periodic thermographic studies to follow progression of lesions seem to be a
useful and reproducible method.
Saxena AK, Willital GH. Department of Pediatric Surgery, Medical University of Graz, Auenbruggerplatz 34, Graz, A-8036, Austria
The aim of this study was to evaluate the feasibility of clinical application of infrared thermography (IRT) in the pediatric population and to identify pathological states that can be diagnosed as well as followed up using this non-invasive technique. In real time computer-assisted IRT, 483 examinations were performed over a period of 10 years from 1990-2000 on 285 patients in the pediatric age group (range 1 week-16 years) presenting with a wide range of pathologies. The temperature was measured in centigrade (degrees C), and color images obtained were computer analyzed and stored on floppy discs. IRT was found to be an excellent noninvasive tool in the follow-up of hemangiomas, vascular
malformations and digit amputations related to re implantation, burns as well as skin and vascular
growth after bio-material implants in newborns with gastroschisis and giant omphaloceles. In the
emergency room, it was a valuable tool for rapid diagnosis of extremity thrombosis, varicoceles,
inflammation, abscesses, gangrene and wound infections. In conclusion, IRT can be performed in
the pediatric age group, is non-invasive, without any biological side effects, requires no sedation or
anesthesia and can be repeated as desired for follow-ups, with objective results that can demonstrated as colored images. Periodic thermographic studies to follow progression of lesions seem to be a
useful and reproducible method.
Monday, June 6, 2016
Timing of the thermographic assessment of burns.
Timing of the thermographic assessment of burns.
The thermographic assessment of burns using infrared imaging has previously been shown to be a useful aid in the estimation of burn depth. In this study, thermographic images of burns, obtained from 65 patients over a 4-year period, were reviewed. ... The results of this study suggest that thermography of burns, to assess depth, should be performed within 3 days following the injury.
The thermographic assessment of burns using infrared imaging has previously been shown to be a useful aid in the estimation of burn depth. In this study, thermographic images of burns, obtained from 65 patients over a 4-year period, were reviewed. ... The results of this study suggest that thermography of burns, to assess depth, should be performed within 3 days following the injury.
Friday, June 3, 2016
Contemporary applications of infrared imaging in medical diagnostics.
Contemporary applications of infrared imaging in medical diagnostics.
Mikulska D. Katedra i Klinika Chorób Skórnych i Wenerycznych Pomorskiej Akademii Medycznej al. Powstanców Wlkp. 72, 70-111 Szczecin.
INTRODUCTION: Thermal imaging is a non-contact, non-invasive diagnostic method for study human body temperature. Therefore infrared thermal imaging finds increasing application in clinical medicine.
PURPOSE: The aim of this paper was to present and discuss the history and applications of thermal imaging in medicine.
MATERIAL AND METHODS: The literature dealing with the history and applications of thermal imaging in medicine has been reviewed.
RESULTS: Medical thermography was born in 1957 when a surgeon, Dr. R. Lawson discovered that his breast cancer patients had higher skin temperature over the cancer area. Since the 1970's thermography has been used in many areas of medicine. Early problems such as low detector sensitivity, but most significantly, poor training of thermography technicians was the source of error in thermography and retarded the acceptance of this technique until 1990. Since that time, thermographic equipment has evolved significantly. Modern thermal imaging systems comprise
technically advanced thermal cameras coupled to computers with sophisticated software solutions. The recorded images are now of good quality and may be further processed to obtain reliable information. Thermography can be applied as a diagnostic tool in oncology, allergic diseases, angiology, plastic surgery, rheumatology, and elsewhere. Contemporary thermal imaging must be performed according to certain principles aimed at reliability and reproducibility of results.
CONCLUSIONS: 1. Thermography is a safe, accurate and, most importantly, a noninvasive diagnostic method in clinical medicine. 2. Ignoring any of the principles worked out by the European Association of Thermology leaves thermography open to error and thus reduces acceptance of this technique in medical diagnostics.
Mikulska D. Katedra i Klinika Chorób Skórnych i Wenerycznych Pomorskiej Akademii Medycznej al. Powstanców Wlkp. 72, 70-111 Szczecin.
INTRODUCTION: Thermal imaging is a non-contact, non-invasive diagnostic method for study human body temperature. Therefore infrared thermal imaging finds increasing application in clinical medicine.
PURPOSE: The aim of this paper was to present and discuss the history and applications of thermal imaging in medicine.
MATERIAL AND METHODS: The literature dealing with the history and applications of thermal imaging in medicine has been reviewed.
RESULTS: Medical thermography was born in 1957 when a surgeon, Dr. R. Lawson discovered that his breast cancer patients had higher skin temperature over the cancer area. Since the 1970's thermography has been used in many areas of medicine. Early problems such as low detector sensitivity, but most significantly, poor training of thermography technicians was the source of error in thermography and retarded the acceptance of this technique until 1990. Since that time, thermographic equipment has evolved significantly. Modern thermal imaging systems comprise
technically advanced thermal cameras coupled to computers with sophisticated software solutions. The recorded images are now of good quality and may be further processed to obtain reliable information. Thermography can be applied as a diagnostic tool in oncology, allergic diseases, angiology, plastic surgery, rheumatology, and elsewhere. Contemporary thermal imaging must be performed according to certain principles aimed at reliability and reproducibility of results.
CONCLUSIONS: 1. Thermography is a safe, accurate and, most importantly, a noninvasive diagnostic method in clinical medicine. 2. Ignoring any of the principles worked out by the European Association of Thermology leaves thermography open to error and thus reduces acceptance of this technique in medical diagnostics.
Wednesday, June 1, 2016
Dynamic infrared imaging of cutaneous melanoma and normal skin in patients treated with BNCT.
Dynamic infrared imaging of cutaneous melanoma and normal skin in patients treated with BNCT.
Santa Cruz GA, Bertotti J, Marín J, González SJ, Gossio S, Alvarez D, Roth BM, Menéndez P, Pereira MD, Albero M, Cubau L, Orellano P, Liberman SJ.
Source
Dpto. de Instrumentación y Control, Comisión Nacional de Energía Atómica, Av. del Libertador 8250 (1429), Buenos Aires, Argentina. santacr@cnea.gov.ar
Abstract
We recently initiated a program aimed to investigate the suitability of dynamic infrared imaging for following-up nodular melanoma patients treated with BNCT. The reason that makes infrared imaging attractive is the fact that it constitutes a functional and non-invasive imaging method, providing information on the normal and abnormal physiologic response of the nervous and vascular systems, as well as the local metabolic rate and inflammatory processes that ultimately appear as differences in the skin temperature. An infrared camera, with a focal plane array of 320 x 240 uncooled ferroelectric detectors is employed, which provides a video stream of the infrared emission in the 7-14 micron wavelength band. A double black-body is used as reference for absolute temperature calibration. After following a protocol for patient preparation and acclimatization, a basal study is performed. Subsequently, the anatomic region of interest is subjected to a provocation test (a cold stimulus), which induces an autonomic vasoconstriction reflex in normal structures, thus enhancing the thermal contrast due to the differences in the vasculature of the different skin regions. Radiation erythema reactions and melanoma nodules possess typically a faster temperature recovery than healthy, non-irradiated skin. However, some other non-pathological structures are also detectable by infrared imaging, (e.g. scars, vessels, arteriovenous anastomoses and injuries), thus requiring a multi-study comparison in order to discriminate the tumor signal. Besides the superficial nodules, which are readily noticeable by infrared imaging, we have detected thermal signals that are coincident with the location of non-palpable nodules, which are observable by CT and ultrasound. Diffuse regions of fast temperature recovery after a cold stimulus were observed between the third and sixth weeks post-BNCT, concurrent with the clinical manifestation of radiation erythema. The location of the erythematous visible and infrared regions is consistent with the 3D dosimetry calculations.
Santa Cruz GA, Bertotti J, Marín J, González SJ, Gossio S, Alvarez D, Roth BM, Menéndez P, Pereira MD, Albero M, Cubau L, Orellano P, Liberman SJ.
Source
Dpto. de Instrumentación y Control, Comisión Nacional de Energía Atómica, Av. del Libertador 8250 (1429), Buenos Aires, Argentina. santacr@cnea.gov.ar
Abstract
We recently initiated a program aimed to investigate the suitability of dynamic infrared imaging for following-up nodular melanoma patients treated with BNCT. The reason that makes infrared imaging attractive is the fact that it constitutes a functional and non-invasive imaging method, providing information on the normal and abnormal physiologic response of the nervous and vascular systems, as well as the local metabolic rate and inflammatory processes that ultimately appear as differences in the skin temperature. An infrared camera, with a focal plane array of 320 x 240 uncooled ferroelectric detectors is employed, which provides a video stream of the infrared emission in the 7-14 micron wavelength band. A double black-body is used as reference for absolute temperature calibration. After following a protocol for patient preparation and acclimatization, a basal study is performed. Subsequently, the anatomic region of interest is subjected to a provocation test (a cold stimulus), which induces an autonomic vasoconstriction reflex in normal structures, thus enhancing the thermal contrast due to the differences in the vasculature of the different skin regions. Radiation erythema reactions and melanoma nodules possess typically a faster temperature recovery than healthy, non-irradiated skin. However, some other non-pathological structures are also detectable by infrared imaging, (e.g. scars, vessels, arteriovenous anastomoses and injuries), thus requiring a multi-study comparison in order to discriminate the tumor signal. Besides the superficial nodules, which are readily noticeable by infrared imaging, we have detected thermal signals that are coincident with the location of non-palpable nodules, which are observable by CT and ultrasound. Diffuse regions of fast temperature recovery after a cold stimulus were observed between the third and sixth weeks post-BNCT, concurrent with the clinical manifestation of radiation erythema. The location of the erythematous visible and infrared regions is consistent with the 3D dosimetry calculations.
Tuesday, May 31, 2016
Interexaminer reliability of infrared thermography for the diagnosis of complex regional pain syndrome.
Inter-examiner reliability of infrared thermography for the diagnosis of complex regional pain syndrome.
Eunjoo Choi Pyung-Bok Lee Francis Sahngun Nahm Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
Skin Research and Technology (Impact Factor: 1.41). 01/2013; DOI: 10.1111/srt.12032
Source: PubMed
ABSTRACT BACKGROUND/PURPOSE: Infrared thermography (IRT) is a useful tool for assessing skin temperature abnormalities in patients with complex regional pain syndrome (CRPS). Although determining regions of interest (ROIs) is an essential process for interpreting thermographic images, there are no validated and standardized guidelines to determine ROIs. Therefore, ROIs may be determined differently by each observer even for the same IRT images, which can result in an important issue for IRT reliability. The purpose of this study was to investigate the inter-examiner reliability of IRT in patients with CRPS.
METHODS: Infrared thermographic images of 28 patients diagnosed with CRPS were reviewed by three independent examiners. The shapes, sizes, and the detailed locations of the ROIs were determined by the investigator's own opinion based on patient history and symptoms. After maximal skin temperature of the ROI was obtained for each patient, the degree of agreement among the three examiners limbs was assessed.
RESULTS: The intraclass correlation coefficient among the three independent raters was 0.865 (95% confidence interval, 0.748-0.933), indicating a high degree of reliability (P < 0.001).
CONCLUSIONS: The reliability of IRT for assessing skin temperature abnormalities in CRPS was high when the ROIs were determined based on patient history and symptoms.
Eunjoo Choi Pyung-Bok Lee Francis Sahngun Nahm Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
Skin Research and Technology (Impact Factor: 1.41). 01/2013; DOI: 10.1111/srt.12032
Source: PubMed
ABSTRACT BACKGROUND/PURPOSE: Infrared thermography (IRT) is a useful tool for assessing skin temperature abnormalities in patients with complex regional pain syndrome (CRPS). Although determining regions of interest (ROIs) is an essential process for interpreting thermographic images, there are no validated and standardized guidelines to determine ROIs. Therefore, ROIs may be determined differently by each observer even for the same IRT images, which can result in an important issue for IRT reliability. The purpose of this study was to investigate the inter-examiner reliability of IRT in patients with CRPS.
METHODS: Infrared thermographic images of 28 patients diagnosed with CRPS were reviewed by three independent examiners. The shapes, sizes, and the detailed locations of the ROIs were determined by the investigator's own opinion based on patient history and symptoms. After maximal skin temperature of the ROI was obtained for each patient, the degree of agreement among the three examiners limbs was assessed.
RESULTS: The intraclass correlation coefficient among the three independent raters was 0.865 (95% confidence interval, 0.748-0.933), indicating a high degree of reliability (P < 0.001).
CONCLUSIONS: The reliability of IRT for assessing skin temperature abnormalities in CRPS was high when the ROIs were determined based on patient history and symptoms.
Labels:
ABNORMALITIES,
CRPS,
infrared,
IRT,
physiology,
skin,
temperature,
THERMOGRAPHY
Friday, May 20, 2016
Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device.
Can rotational atherectomy cause thermal tissue damage? A study of the potential heating and thermal tissue effects of a rotational atherectomy device.
Gehani AA, Rees MR; Cardiac Research Unit, Killingbeck Hospital, Leeds, United Kingdom.
PURPOSE: Thermal tissue damage (TTD) is customarily associated with some lasers. The thermal potential of rotational atherectomy (RA) devices is unknown. We investigated the temperature profile and potential TTD as well as the value of fluid flushing of an RA device.
METHODS: We used a high-resolution infrared imaging system that can detect changes as small as 0.1 degree C to measure the temperature changes at the tip of a fast RA device with and without fluid flushing. To assess TTD, segments of porcine aorta were subjected to the rotating tip under controlled conditions, stained by a special histochemical stain (picrisirius red) and examined under normal and polarized light microscopy.
RESULTS: There was significant heating of the rotating cam. The mean "peak" temperature rise was 52.8 +/- 16.9 degrees C. This was related to rotational speed; thus the "peak" temperature rise was 88.3 +/- 12.6 degrees C at 80,000 rpm and 17.3 +/- 3.8 degrees C at 20,000 rpm (p < 0.001, t-test). Fluid flushing at 18 ml/min reduced, but did not abolish, heating of the device (11.8 +/- 2.9 degrees C). A crater was observed in all segments exposed to the rotating tip. The following features were most notable: (i) A zone of "thermal" tissue damage extended radially from the crater reaching adventitia in some sections, especially at high speeds. This zone showed markedly reduced or absent birefringence. (ii) Fluid flushing of the catheter reduced the above changes but increased the incidence and extent of dissections in the media, especially when combined with high atherectomy speeds. (iii) These changes were observed in five of six specimens exposed to RA without flushing, but in only one of six with flushing (p < 0.05). (iv) None of the above changes was seen in control segments.
CONCLUSION: RA is capable of generating significant heat and potential TTD. Fluid flushing reduced heating and TTD. These findings warrant further studies in vivo, and may influence the design of atherectomy devices.
Gehani AA, Rees MR; Cardiac Research Unit, Killingbeck Hospital, Leeds, United Kingdom.
PURPOSE: Thermal tissue damage (TTD) is customarily associated with some lasers. The thermal potential of rotational atherectomy (RA) devices is unknown. We investigated the temperature profile and potential TTD as well as the value of fluid flushing of an RA device.
METHODS: We used a high-resolution infrared imaging system that can detect changes as small as 0.1 degree C to measure the temperature changes at the tip of a fast RA device with and without fluid flushing. To assess TTD, segments of porcine aorta were subjected to the rotating tip under controlled conditions, stained by a special histochemical stain (picrisirius red) and examined under normal and polarized light microscopy.
RESULTS: There was significant heating of the rotating cam. The mean "peak" temperature rise was 52.8 +/- 16.9 degrees C. This was related to rotational speed; thus the "peak" temperature rise was 88.3 +/- 12.6 degrees C at 80,000 rpm and 17.3 +/- 3.8 degrees C at 20,000 rpm (p < 0.001, t-test). Fluid flushing at 18 ml/min reduced, but did not abolish, heating of the device (11.8 +/- 2.9 degrees C). A crater was observed in all segments exposed to the rotating tip. The following features were most notable: (i) A zone of "thermal" tissue damage extended radially from the crater reaching adventitia in some sections, especially at high speeds. This zone showed markedly reduced or absent birefringence. (ii) Fluid flushing of the catheter reduced the above changes but increased the incidence and extent of dissections in the media, especially when combined with high atherectomy speeds. (iii) These changes were observed in five of six specimens exposed to RA without flushing, but in only one of six with flushing (p < 0.05). (iv) None of the above changes was seen in control segments.
CONCLUSION: RA is capable of generating significant heat and potential TTD. Fluid flushing reduced heating and TTD. These findings warrant further studies in vivo, and may influence the design of atherectomy devices.
Thursday, May 19, 2016
Effectiveness of a noninvasive digital infrared thermal imaging system in the detection of breast cancer.
Effectiveness of a noninvasive digital infrared thermal imaging system in the detection of breast cancer.
Arora N, Martins D, Ruggerio D, Tousimis E, Swistel AJ, Osborne MP, Simmons RM.
Department of Surgery, New York Presbyterian Hospital-Cornell, New York, NY, USA.
BACKGROUND: Digital infrared thermal imaging (DITI) has resurfaced in this era of modernized computer technology. Its role in the detection of breast cancer is evaluated.
METHODS: In this prospective clinical trial, 92 patients for whom a breast biopsy was recommended based on prior mammogram or ultrasound underwent DITI. Three scores were generated: an overall risk score in the screening mode, a clinical score based on patient information, and a third assessment by artificial neural network.
RESULTS: Sixty
of 94 biopsies were malignant and 34 were benign. DITI identified 58 of 60 malignancies, with 97% sensitivity, 44% specificity, and 82% negative predictive value depending on the mode used. Compared to an overall risk score of 0, a score of 3 or greater was significantly more likely to be associated with malignancy (30% vs 90%, P <.03).
CONCLUSION: DITI is a valuable adjunct to mammography and ultrasound, especially in women with dense breast parenchyma.
Arora N, Martins D, Ruggerio D, Tousimis E, Swistel AJ, Osborne MP, Simmons RM.
Department of Surgery, New York Presbyterian Hospital-Cornell, New York, NY, USA.
BACKGROUND: Digital infrared thermal imaging (DITI) has resurfaced in this era of modernized computer technology. Its role in the detection of breast cancer is evaluated.
METHODS: In this prospective clinical trial, 92 patients for whom a breast biopsy was recommended based on prior mammogram or ultrasound underwent DITI. Three scores were generated: an overall risk score in the screening mode, a clinical score based on patient information, and a third assessment by artificial neural network.
RESULTS: Sixty
of 94 biopsies were malignant and 34 were benign. DITI identified 58 of 60 malignancies, with 97% sensitivity, 44% specificity, and 82% negative predictive value depending on the mode used. Compared to an overall risk score of 0, a score of 3 or greater was significantly more likely to be associated with malignancy (30% vs 90%, P <.03).
CONCLUSION: DITI is a valuable adjunct to mammography and ultrasound, especially in women with dense breast parenchyma.
Wednesday, May 11, 2016
Infrared thermography in newborns: the first hour after birth.
Infrared thermography in newborns: the first hour after birth.
Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R. Department of Pediatrics, University of Graz, Austria.
"OBJECTIVE: It was the aim of this study to investigate the surface temperature in newborns within the first hour after delivery. Furthermore, the influence of different environmental conditions with regard to surface temperature was documented.
METHODS: Body surface temperature was recorded under several environmental conditions by use of infrared thermography. 42 newborns, all delivered at term and with weight appropriate for date, were investigated under controlled conditions.
RESULTS: The surface temperature immediately after birth shows a uniform picture of the whole body; however, it is significantly lower than the core temperature. Soon after birth, peripheral sites become cooler whereas a constant temperature is maintained at the trunk. Bathing in warm water again leads to a more even temperature profile. Radiant heaters and skin-to-skin contact with the mother are both effective methods to prevent heat loss in neonates.
CONCLUSIONS: Infrared thermography is a simple and reliable tool for the measurement of skin temperature profiles in neonates. Without the need of direct skin contact, it may be helpful for optimizing environmental conditions at delivery suites and neonatal intensive care units."
Ref. S. Karger AG, Basel
Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R. Department of Pediatrics, University of Graz, Austria.
"OBJECTIVE: It was the aim of this study to investigate the surface temperature in newborns within the first hour after delivery. Furthermore, the influence of different environmental conditions with regard to surface temperature was documented.
METHODS: Body surface temperature was recorded under several environmental conditions by use of infrared thermography. 42 newborns, all delivered at term and with weight appropriate for date, were investigated under controlled conditions.
RESULTS: The surface temperature immediately after birth shows a uniform picture of the whole body; however, it is significantly lower than the core temperature. Soon after birth, peripheral sites become cooler whereas a constant temperature is maintained at the trunk. Bathing in warm water again leads to a more even temperature profile. Radiant heaters and skin-to-skin contact with the mother are both effective methods to prevent heat loss in neonates.
CONCLUSIONS: Infrared thermography is a simple and reliable tool for the measurement of skin temperature profiles in neonates. Without the need of direct skin contact, it may be helpful for optimizing environmental conditions at delivery suites and neonatal intensive care units."
Ref. S. Karger AG, Basel
Labels:
baby,
birth,
infrared,
neonates,
newborns,
peripheral,
physiology,
skin,
THERMOGRAPHY
Monday, May 9, 2016
Peripheral facial paralysis aided by infrared thermography.
Peripheral facial paralysis aided by infrared thermography.
We have carried out clinical observations on 34 patients with peripheral facial paralysis treated by
acupuncture therapy prescribed according to selection of treatment regimen on the basis of facial
thermogram and temperature. A comparison was made with a control group of 97 patients who received conventional acupuncture therapy only. It was found that: (1) The cure rate in the group of selecting acupoints by thermogram (hereinafter referred to as the thermography--aided treatment group) was 67.65%, with a marked improvement rate of 26.40%; while the cure rate of the conventional acupuncture treatment group (hereinafter called the conventional treatment group) was 46.39%, the marked improvement rate being 29.90%, indicating a significant difference in therapeutic efficacy between the two groups (P less than 0.02). (2) The average duration of acupuncture therapy for the thermography aided treatment group was 6.02 weeks, whereas that for the conventional treatment group, 24 weeks. There was also a significant difference between the two groups (p less than 0.01). (3) During the entire therapeutic course, 25.2 sessions of treatment were given on the average in the thermography--aided treatment group, and 78.8 sessions in the conventional treatment group, showing a very significant difference (P less than 0.001). The present thermography--aided method exhibits advantages over the conventional one in enhancing the cure rate and shortening the duration of treatment, which is worthy to be popularized in clinical practice. It is also of certain significance in standardization and scientification of acupuncture therapy.
Zhang D; Wei Z; Wen B; Gao H; Peng Y; Wang F.
We have carried out clinical observations on 34 patients with peripheral facial paralysis treated by
acupuncture therapy prescribed according to selection of treatment regimen on the basis of facial
thermogram and temperature. A comparison was made with a control group of 97 patients who received conventional acupuncture therapy only. It was found that: (1) The cure rate in the group of selecting acupoints by thermogram (hereinafter referred to as the thermography--aided treatment group) was 67.65%, with a marked improvement rate of 26.40%; while the cure rate of the conventional acupuncture treatment group (hereinafter called the conventional treatment group) was 46.39%, the marked improvement rate being 29.90%, indicating a significant difference in therapeutic efficacy between the two groups (P less than 0.02). (2) The average duration of acupuncture therapy for the thermography aided treatment group was 6.02 weeks, whereas that for the conventional treatment group, 24 weeks. There was also a significant difference between the two groups (p less than 0.01). (3) During the entire therapeutic course, 25.2 sessions of treatment were given on the average in the thermography--aided treatment group, and 78.8 sessions in the conventional treatment group, showing a very significant difference (P less than 0.001). The present thermography--aided method exhibits advantages over the conventional one in enhancing the cure rate and shortening the duration of treatment, which is worthy to be popularized in clinical practice. It is also of certain significance in standardization and scientification of acupuncture therapy.
Zhang D; Wei Z; Wen B; Gao H; Peng Y; Wang F.
Wednesday, May 4, 2016
Screening for fever by remote-sensing infrared thermographic camera.
Screening for fever by remote-sensing infrared thermographic camera.
Chan LS et al.; Department of Earth Sciences, The University of Hong Kong, Hong Kong.
Following the severe acute respiratory syndrome (SARS) outbreak, remote-sensing infrared
thermography (IRT) has been advocated as a possible means of screening for fever in travelers
at airports and border crossings, but its applicability has not been established. We therefore set
out to evaluate (1) the feasibility of IRT imaging to identify subjects with fever, and (2) the optimal
instrumental configuration and validity for such testing. CONCLUSIONS: IRT readings from the
side of the face, especially from the ear at 0.5 m, yielded the most reliable, precise and consistent
estimates of conventionally determined body temperatures. Our results have important
implications for walk-through IRT scanning/screening systems at airports and border crossings,
particularly as the point prevalence of fever in such subjects would be very low.
Chan LS et al.; Department of Earth Sciences, The University of Hong Kong, Hong Kong.
Following the severe acute respiratory syndrome (SARS) outbreak, remote-sensing infrared
thermography (IRT) has been advocated as a possible means of screening for fever in travelers
at airports and border crossings, but its applicability has not been established. We therefore set
out to evaluate (1) the feasibility of IRT imaging to identify subjects with fever, and (2) the optimal
instrumental configuration and validity for such testing. CONCLUSIONS: IRT readings from the
side of the face, especially from the ear at 0.5 m, yielded the most reliable, precise and consistent
estimates of conventionally determined body temperatures. Our results have important
implications for walk-through IRT scanning/screening systems at airports and border crossings,
particularly as the point prevalence of fever in such subjects would be very low.
Labels:
acute,
camera,
fever,
infrared,
IRT,
respiratory,
SARS,
THERMOGRAPHIC,
travel
Friday, April 29, 2016
Foot evaluation by infrared imaging.
Foot evaluation by infrared imaging.
DiBenedetto M, Yoshida M, Sharp M, Jones B.
Source
University of Virginia, Department of Physical Medicine and Rehabilitation, 545 Ray C. Hunt Drive, Suite 240, Charlottesville, VA 22903-2981, USA.
Abstract
For better assessment of foot injury severity during basic military training, we evaluated a simple
noninvasive technique: thermography. With this infrared imaging method, we determined normal foot
parameters (from 30 soldiers before training), thermographic findings in different foot stress fractures (from 30 soldiers so diagnosed), and normal responses to abnormal stresses in 30 trainees who underwent the same training as the previous group but did not have musculoskeletal complaints. We found that normal foot thermograms show onion peel-like progressive cooling on the plantar surface, with a medially located warm center at the instep. Thermograms of injured feet show areas of increased heat, but excessive weight bearing pressures on feet, new shoes, or boots also cause increased infrared emission even without discomfort. Differentiation remains difficult; however, thermography can detect injury early. It does not reveal exact diagnoses, but its greatest benefit is easy follow-up to monitor severity and healing.
DiBenedetto M, Yoshida M, Sharp M, Jones B.
Source
University of Virginia, Department of Physical Medicine and Rehabilitation, 545 Ray C. Hunt Drive, Suite 240, Charlottesville, VA 22903-2981, USA.
Abstract
For better assessment of foot injury severity during basic military training, we evaluated a simple
noninvasive technique: thermography. With this infrared imaging method, we determined normal foot
parameters (from 30 soldiers before training), thermographic findings in different foot stress fractures (from 30 soldiers so diagnosed), and normal responses to abnormal stresses in 30 trainees who underwent the same training as the previous group but did not have musculoskeletal complaints. We found that normal foot thermograms show onion peel-like progressive cooling on the plantar surface, with a medially located warm center at the instep. Thermograms of injured feet show areas of increased heat, but excessive weight bearing pressures on feet, new shoes, or boots also cause increased infrared emission even without discomfort. Differentiation remains difficult; however, thermography can detect injury early. It does not reveal exact diagnoses, but its greatest benefit is easy follow-up to monitor severity and healing.
Thursday, April 28, 2016
Infrared thermography. Its role in dental research with particular reference to craniomandibular disorders.
Infrared thermography. Its role in dental research with particular reference to craniomandibular disorders.
Biagioni PA, Longmore RB, McGimpsey JG, Lamey PJ.
Source
School of Clinical Dentistry, Queen's University of Belfast, UK.
Abstract
The use of infrared thermography in dentistry has been minimal, principally due to technological inadequacies of previous thermal imaging systems. However, with the ever-developing advancement in technology, current systems are capable of producing real-time, highly sensitive digitized thermal images. This development has led to an increased use of infrared imaging within both medical and dental research. The present paper describes these techniques and their previous applications within dentistry, and, through the use of a pilot study, highlights possible future applications in the assessment of craniomandibular disorders.
Biagioni PA, Longmore RB, McGimpsey JG, Lamey PJ.
Source
School of Clinical Dentistry, Queen's University of Belfast, UK.
Abstract
The use of infrared thermography in dentistry has been minimal, principally due to technological inadequacies of previous thermal imaging systems. However, with the ever-developing advancement in technology, current systems are capable of producing real-time, highly sensitive digitized thermal images. This development has led to an increased use of infrared imaging within both medical and dental research. The present paper describes these techniques and their previous applications within dentistry, and, through the use of a pilot study, highlights possible future applications in the assessment of craniomandibular disorders.