Showing posts with label physiology. Show all posts
Showing posts with label physiology. Show all posts

Friday, June 17, 2016

Quantitative visualization and detection of skin cancer using dynamic thermal imaging.

Quantitative visualization and detection of skin cancer using dynamic thermal imaging.
Herman C1, Cetingul MP.

Abstract
In 2010 approximately 68,720 melanomas will be diagnosed in the US alone, with around 8,650 resulting in death. To date, the only effective treatment for melanoma remains surgical excision, therefore, the key to extended survival is early detection. Considering the large numbers of patients diagnosed every year and the limitations in accessing specialized care quickly, the development of objective in vivo diagnostic instruments to aid the diagnosis is essential. New techniques to detect skin cancer, especially non-invasive diagnostic tools, are being explored in numerous laboratories. Along with the surgical methods, techniques such as digital photography, dermoscopy, multi-spectral imaging systems (MelaFind), laser-based systems (confocal scanning laser microscopy, laser Doppler perfusion imaging, optical coherence tomography), ultrasound, magnetic resonance imaging, are being tested. Each technique offers unique advantages and disadvantages, many of which pose a compromise between effectiveness and accuracy versus ease of use and cost considerations. Details about these techniques and comparisons are available in the literature. Infrared (IR) imaging was shown to be a useful method to diagnose the signs of certain diseases by measuring the local skin temperature. There is a large body of evidence showing that disease or deviation from normal functioning are accompanied by changes of the temperature of the body, which again affect the temperature of the skin. Accurate data about the temperature of the human body and skin can provide a wealth of information on the processes responsible for heat generation and thermoregulation, in particular the deviation from normal conditions, often caused by disease. However, IR imaging has not been widely recognized in medicine due to the premature use of the technology several decades ago, when temperature measurement accuracy and the spatial resolution were inadequate and sophisticated image processing tools were unavailable. This situation changed dramatically in the late 1990s-2000s. Advances in IR instrumentation, implementation of digital image processing algorithms and dynamic IR imaging, which enables scientists to analyze not only the spatial, but also the temporal thermal behavior of the skin, allowed breakthroughs in the field. In our research, we explore the feasibility of IR imaging, combined with theoretical and experimental studies, as a cost effective, non-invasive, in vivo optical measurement technique for tumor detection, with emphasis on the screening and early detection of melanoma. In this study, we show data obtained in a patient study in which patients that possess a pigmented lesion with a clinical indication for biopsy are selected for imaging. We compared the difference in thermal responses between healthy and malignant tissue and compared our data with biopsy results. We concluded that the increased metabolic activity of the melanoma lesion can be detected by dynamic infrared imaging.

Thursday, June 16, 2016

Interexaminer reliability of infrared thermography for the diagnosis of complex regional pain syndrome.

Inter-examiner reliability of infrared thermography for the diagnosis of complex regional pain syndrome. 

Eunjoo Choi

Pyung-Bok Lee

Francis Sahngun Nahm

Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea. 

ABSTRACT BACKGROUND/PURPOSE: Infrared thermography (IRT) is a useful tool for assessing skin temperature abnormalities in patients with complex regional pain syndrome (CRPS). Although determining regions of interest (ROIs) is an essential process for interpreting thermographic images, there are no validated and standardized guidelines to determine ROIs. Therefore, ROIs may be determined differently by each observer even for the same IRT images, which can result in an important issue for IRT reliability. The purpose of this study was to investigate the inter-examiner reliability of IRT in patients with CRPS.

METHODS: Infrared thermographic images of 28 patients diagnosed with CRPS were reviewed by three independent examiners. The shapes, sizes, and the detailed locations of the ROIs were determined by the investigator's own opinion based on patient history and symptoms. After maximal skin temperature of the ROI was obtained for each patient, the degree of agreement among the three examiners limbs was assessed.

RESULTS: The intraclass correlation coefficient among the three independent raters was 0.865 (95% confidence interval, 0.748-0.933), indicating a high degree of reliability (P < 0.001).

CONCLUSIONS: The reliability of IRT for assessing skin temperature abnormalities in CRPS was high when the ROIs were determined based on patient history and symptoms.

Friday, June 10, 2016

Application of thermography for non-invasive diagnosis of thyroid gland disease.

Application of thermography for non-invasive diagnosis of thyroid gland disease.
Helmy A1, Holdmann M, Rizkalla M.

Abstract
In this paper, a computer-based prototype device was designed based on an economical noninvasive system that could detect and display the relative skin temperature variations present in human patients suffering from thyroid disorders. Such a system could be used to augment the normal procedures followed by the physician in diagnosing the thyroid to detect areas of hyperactivity within the gland. Because a hyperactive nodule is a center of increased blood flow and chemical activity, it might be also a center of heat production that is detectable by thermal sensing. This paper also presents a finite-element analysis (FEA) of a hot thyroid nodule that is used for investigating the temperature distribution in conjunction with the prototype. The instrumentation model built was based on actual dimensional human model for thyroid nodules obtained from various patients. A software program was written in Visual Basic to detect the temperature distribution around the hot spot. The software also incorporates means to minimize the thermal noise associated with the body temperature. The FEA utilizes the same boundary values used in the practical settings. This includes initial values of temperatures for the hot spot and its surroundings. The results of the finite-element simulation assisted in the selection of the solid state sensors that were used in the instrumentation of the thermographic system. The selected sensors were calibrated for their functionality and dynamic performance according to the specifications. The new noninvasive diagnostic technique was applied to patients having Graves' diseases at the Indiana University (IU) Hospital, and compared with the existing scheme that utilizes I Scan. The results of the new diagnostic method were in good agreement with the current existing method.

Tuesday, June 7, 2016

Thermal signature analysis as a novel method for evaluating inflammatory arthritis activity.

Thermal signature analysis as a novel method for evaluating inflammatory arthritis activity.
Brenner M, Braun C, Oster M, Gulko PS. North Shore-LIJ Research Institute, United States.

OBJECTIVES: To determine the potential usefulness of a novel thermal imaging technology to evaluate and monitor inflammatory arthritis activity in small joints using rat models, and to determine whether thermal changes can be used to detect pre-clinical stages of synovitis.

METHODS: Three different rat strains were studied in a mono-articular model of inflammatory arthritis of the ankle induced with an intraarticular (IA) injection of complete Freund's adjuvant (CFA), and compared with the contra-lateral ankle injected with normal saline. Arthritis activity and severity scores, ankle diameters, pain related posture scores, and thermal images were obtained at ten different time-points between 0h (before induction) and day 7. The pristane-induced arthritis (PIA) model was used to study pre-clinical synovitis. 

RESULTS: Rats developed similar ankle arthritis detected 6h after the IA injection of CFA, which persisted for seven days. All ankle clinical parameters, including arthritis activity and severity scores, significantly correlated with ankle thermal imaging changes in the mono-arthritis model (P<0.003). No thermal imaging changes were detected in pre-clinical stages of PIA. However, PIA onset coincided with increased ankle thermal signature.

CONCLUSION:Thermal measurements significantly correlated with arthritis activity and severity parameters. This technology was highly sensitive and could directly measure two cardinal signs of inflammation (warmth and edema - based on ankle diameter) in an area (ankle) that is less than half the size of a human interphalangeal joint, suggesting a potential use to monitor drug responses of rheumatoid arthritis in drug trials or clinical practice.

Monday, June 6, 2016

Timing of the thermographic assessment of burns.

Timing of the thermographic assessment of burns. 

The thermographic assessment of burns using infrared imaging has previously been shown to be a useful aid in the estimation of burn depth. In this study, thermographic images of burns, obtained from 65 patients over a 4-year period, were reviewed. ... The results of this study suggest that thermography of burns, to assess depth, should be performed within 3 days following the injury.

Wednesday, June 1, 2016

Dynamic infrared imaging of cutaneous melanoma and normal skin in patients treated with BNCT.

Dynamic infrared imaging of cutaneous melanoma and normal skin in patients treated with BNCT.
Santa Cruz GA, Bertotti J, Marín J, González SJ, Gossio S, Alvarez D, Roth BM, Menéndez P, Pereira MD, Albero M, Cubau L, Orellano P, Liberman SJ.

Source
Dpto. de Instrumentación y Control, Comisión Nacional de Energía Atómica, Av. del Libertador 8250 (1429), Buenos Aires, Argentina. santacr@cnea.gov.ar

Abstract
We recently initiated a program aimed to investigate the suitability of dynamic infrared imaging for following-up nodular melanoma patients treated with BNCT. The reason that makes infrared imaging attractive is the fact that it constitutes a functional and non-invasive imaging method, providing information on the normal and abnormal physiologic response of the nervous and vascular systems, as well as the local metabolic rate and inflammatory processes that ultimately appear as differences in the skin temperature. An infrared camera, with a focal plane array of 320 x 240 uncooled ferroelectric detectors is employed, which provides a video stream of the infrared emission in the 7-14 micron wavelength band. A double black-body is used as reference for absolute temperature calibration. After following a protocol for patient preparation and acclimatization, a basal study is performed. Subsequently, the anatomic region of interest is subjected to a provocation test (a cold stimulus), which induces an autonomic vasoconstriction reflex in normal structures, thus enhancing the thermal contrast due to the differences in the vasculature of the different skin regions. Radiation erythema reactions and melanoma nodules possess typically a faster temperature recovery than healthy, non-irradiated skin. However, some other non-pathological structures are also detectable by infrared imaging, (e.g. scars, vessels, arteriovenous anastomoses and injuries), thus requiring a multi-study comparison in order to discriminate the tumor signal. Besides the superficial nodules, which are readily noticeable by infrared imaging, we have detected thermal signals that are coincident with the location of non-palpable nodules, which are observable by CT and ultrasound. Diffuse regions of fast temperature recovery after a cold stimulus were observed between the third and sixth weeks post-BNCT, concurrent with the clinical manifestation of radiation erythema. The location of the erythematous visible and infrared regions is consistent with the 3D dosimetry calculations.

Tuesday, May 31, 2016

Interexaminer reliability of infrared thermography for the diagnosis of complex regional pain syndrome.

Inter-examiner reliability of infrared thermography for the diagnosis of complex regional pain syndrome.
Eunjoo Choi Pyung-Bok Lee Francis Sahngun Nahm Department of Anesthesiology and Pain Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
Skin Research and Technology (Impact Factor: 1.41). 01/2013; DOI: 10.1111/srt.12032

Source: PubMed

ABSTRACT BACKGROUND/PURPOSE: Infrared thermography (IRT) is a useful tool for assessing skin temperature abnormalities in patients with complex regional pain syndrome (CRPS). Although determining regions of interest (ROIs) is an essential process for interpreting thermographic images, there are no validated and standardized guidelines to determine ROIs. Therefore, ROIs may be determined differently by each observer even for the same IRT images, which can result in an important issue for IRT reliability. The purpose of this study was to investigate the inter-examiner reliability of IRT in patients with CRPS.

METHODS: Infrared thermographic images of 28 patients diagnosed with CRPS were reviewed by three independent examiners. The shapes, sizes, and the detailed locations of the ROIs were determined by the investigator's own opinion based on patient history and symptoms. After maximal skin temperature of the ROI was obtained for each patient, the degree of agreement among the three examiners limbs was assessed.

RESULTS: The intraclass correlation coefficient among the three independent raters was 0.865 (95% confidence interval, 0.748-0.933), indicating a high degree of reliability (P < 0.001).

CONCLUSIONS: The reliability of IRT for assessing skin temperature abnormalities in CRPS was high when the ROIs were determined based on patient history and symptoms.

Wednesday, May 18, 2016

The analgesic efficacy of bee venom acupuncture for knee osteoarthritis: a comparative study with needle acupuncture.

The analgesic efficacy of bee venom acupuncture for knee osteoarthritis: a comparative study with needle acupuncture.

Kwon YB, Kim JH, Yoon JH, Lee JD, Han HJ, Mar WC, Beitz AJ, Lee JH. Department of Veterinary Physiology, College of Veterinary Medicine and School of Agricultural Biotechnology, Seoul National University, Suwon, Korea.

The aim of this investigation was to determine whether bee venom (BV) administered directly into an acupoint was a clinically effective and safe method for relieving the pain of patients with knee osteoarthritis (OA) as compared to traditional needle acupuncture. We evaluated the efficacy of BV acupuncture using both pain relief scores and computerized infrared thermography (IRT) following 4 weeks of BV acupuncture treatment. We observed that a significantly higher proportion of subjects receiving BV acupuncture reported substantial pain relief as compared with those receiving traditional needle acupuncture therapy. Furthermore, the IRT score was significantly improved and paralleled the level of pain relief.

Friday, May 13, 2016

Thyroid diagnosis by thermogram sequence analysis.

Thyroid diagnosis by thermogram sequence analysis.
Chan FH, So AT, Kung AW, Lam FK, Yip HC. Source Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong.

Abstract
A computerized thermal imaging system for thyroid diagnosis was developed by the authors and it was discovered that the rate of changes of temperature, rather than the absolute values, associated with a sequence of thermograms could help the medical doctors to identify clinical disorders. In order to further enhance the diagnostic capabilities and speed, a new method for medical thermogram analysis has been developed that compresses a sequence of thermograms into one thermogram while retaining the important information such as the geometrical patterns of the objects and the rate of temperature changes of each pixel within the images. As motion artifacts are unavoidable when a patient undergoes minutes of thermogram recording, direct comparison between images is deemed impossible. A high speed image matching algorithm has been developed to provide an absolute geometrical foundation for pixel-to-pixel comparison. The rate of change of temperature of a particular pixel along the sequence is represented by one single parameter after a process of temperature integration which can then be converted into a corresponding gray level for display. The resultant compressed thermogram can give a clear distinction between problem areas and normal ones. Although our emphasis is on thyroid diagnosis, it is anticipated that this new technique can be applicable to other areas of a human body.

Wednesday, May 11, 2016

Infrared thermography in newborns: the first hour after birth.

Infrared thermography in newborns: the first hour after birth.
Christidis I, Zotter H, Rosegger H, Engele H, Kurz R, Kerbl R. Department of Pediatrics, University of Graz, Austria.
"OBJECTIVE: It was the aim of this study to investigate the surface temperature in newborns within the first hour after delivery. Furthermore, the influence of different environmental conditions with regard to surface temperature was documented.
METHODS: Body surface temperature was recorded under several environmental conditions by use of infrared thermography. 42 newborns, all delivered at term and with weight appropriate for date, were investigated under controlled conditions.
RESULTS: The surface temperature immediately after birth shows a uniform picture of the whole body; however, it is significantly lower than the core temperature. Soon after birth, peripheral sites become cooler whereas a constant temperature is maintained at the trunk. Bathing in warm water again leads to a more even temperature profile. Radiant heaters and skin-to-skin contact with the mother are both effective methods to prevent heat loss in neonates.
CONCLUSIONS: Infrared thermography is a simple and reliable tool for the measurement of skin temperature profiles in neonates. Without the need of direct skin contact, it may be helpful for optimizing environmental conditions at delivery suites and neonatal intensive care units."
Ref. S. Karger AG, Basel

Tuesday, May 10, 2016

Thermographic investigation of osseous stress pathology.

Thermographic investigation of osseous stress pathology.
Arthur DT, Khan MM, Barclay LC. Source Faculty of Science and Engineering, Curtin University of Technology Perth, WA 6102, AUS. masood.khan@curtin.edu.au

Abstract
The debilitating pathology of stress fracture accounts for 10% of all athletic injuries[2], with prevalence as high as 20% in modern military basic training cohorts [3]. Increasing concerns surrounding adverse effects of radiology [5], combined with the 12.5% contribution of diagnostic imaging to Australian Medicare benefits paid in 2009-10 [6], have prompted the search for alternative/adjunct electronic decision support systems[7]. Within conducive physio-anatomic milieu, thermal infrared imaging (TIRI) may feasibly be used to remotely detect and topographically map diagnostically useful signs of supra-threshold thermodynamic pathophysiology. This paper details a three month clinical pilot study into TIRI-based detection of osseous stress pathology in the lower legs of Australian Army basic trainees. A data set of over 500 TIRI's was amassed. The apparent 'normal' thermal profile of the anterior aspect of the asymptomatic lower leg is topographically defined and validated against current thermophysiological theory [8] via cadaveric dissection.

Monday, May 9, 2016

Peripheral facial paralysis aided by infrared thermography.

Peripheral facial paralysis aided by infrared thermography.
We have carried out clinical observations on 34 patients with peripheral facial paralysis treated by
acupuncture therapy prescribed according to selection of treatment regimen on the basis of facial
thermogram and temperature. A comparison was made with a control group of 97 patients who received conventional acupuncture therapy only. It was found that: (1) The cure rate in the group of selecting acupoints by thermogram (hereinafter referred to as the thermography--aided treatment group) was 67.65%, with a marked improvement rate of 26.40%; while the cure rate of the conventional acupuncture treatment group (hereinafter called the conventional treatment group) was 46.39%, the marked improvement rate being 29.90%, indicating a significant difference in therapeutic efficacy between the two groups (P less than 0.02). (2) The average duration of acupuncture therapy for the thermography aided treatment group was 6.02 weeks, whereas that for the conventional treatment group, 24 weeks. There was also a significant difference between the two groups (p less than 0.01). (3) During the entire therapeutic course, 25.2 sessions of treatment were given on the average in the thermography--aided treatment group, and 78.8 sessions in the conventional treatment group, showing a very significant difference (P less than 0.001). The present thermography--aided method exhibits advantages over the conventional one in enhancing the cure rate and shortening the duration of treatment, which is worthy to be popularized in clinical practice. It is also of certain significance in standardization and scientification of acupuncture therapy.

Zhang D; Wei Z; Wen B; Gao H; Peng Y; Wang F.

Wednesday, April 27, 2016

Evaluation of provocation test monitoring palmoplantar temperature with the use of thermography for diagnosis of focal tonsillar infection in palmoplantar pustulosis.



Evaluation of provocation test monitoring palmoplantar temperature with the use of thermography for diagnosis of focal tonsillar infection in palmoplantar pustulosis.
Source
Department of Dermatology, Nara Medical University, 840 Shijo-cho Kashihara, 634-8522, Nara, Japan. asadah@naramed-u.ac.jp
Abstract
BACKGROUND:
Since focal tonsillar infections are often associated with palmoplantar pustulosis (PPP), provocation tests have been performed for preoperative evaluation of tonsillectomy. However, these tests have not been fully established.
OBJECTIVES:
To introduce a more sensitive operative indication for tonsillectomy to the patients with PPP, we have monitored the temperature after provocation tests at palmoplantar sites, as measured by thermography, and we hypothesized that this methodology may lead to a more sensitive marker for tonsillectomy.
METHODS:
Twenty-two PPP patients with/without clinical tonsillitis were included in this study. After mechanical tonsillar massage, using infrared thermography, we have monitored the surface temperature at palmoplantar sites of 22 patients with PPP, five chronic tonsillitis patients without PPP, and four healthy controls, to compare the findings with the skin lesional outcome after tonsillectomy.
RESULTS:
There was a significant relationship between the effects of tonsillectomy and the results of provocation tests assessed by thermography. The sensitivity, specificity, and efficiency of the provocation tests with thermography of detecting a favorable outcome of tonsillectomy were 75.0, 83.3, and 77.3%, respectively, while those of the provocation tests as estimated with the conventional criteria were 37.5, 83.3, and 50.0%, respectively.
CONCLUSION:
Our results suggest that a new indicator using non-invasive thermography for the provocation tests is useful in predicting the effects of tonsillectomy for PPP.