Friday, May 13, 2016

Thyroid diagnosis by thermogram sequence analysis.

Thyroid diagnosis by thermogram sequence analysis.
Chan FH, So AT, Kung AW, Lam FK, Yip HC. Source Department of Electrical and Electronic Engineering, University of Hong Kong, Hong Kong.

Abstract
A computerized thermal imaging system for thyroid diagnosis was developed by the authors and it was discovered that the rate of changes of temperature, rather than the absolute values, associated with a sequence of thermograms could help the medical doctors to identify clinical disorders. In order to further enhance the diagnostic capabilities and speed, a new method for medical thermogram analysis has been developed that compresses a sequence of thermograms into one thermogram while retaining the important information such as the geometrical patterns of the objects and the rate of temperature changes of each pixel within the images. As motion artifacts are unavoidable when a patient undergoes minutes of thermogram recording, direct comparison between images is deemed impossible. A high speed image matching algorithm has been developed to provide an absolute geometrical foundation for pixel-to-pixel comparison. The rate of change of temperature of a particular pixel along the sequence is represented by one single parameter after a process of temperature integration which can then be converted into a corresponding gray level for display. The resultant compressed thermogram can give a clear distinction between problem areas and normal ones. Although our emphasis is on thyroid diagnosis, it is anticipated that this new technique can be applicable to other areas of a human body.

Monday, May 9, 2016

Peripheral facial paralysis aided by infrared thermography.

Peripheral facial paralysis aided by infrared thermography.
We have carried out clinical observations on 34 patients with peripheral facial paralysis treated by
acupuncture therapy prescribed according to selection of treatment regimen on the basis of facial
thermogram and temperature. A comparison was made with a control group of 97 patients who received conventional acupuncture therapy only. It was found that: (1) The cure rate in the group of selecting acupoints by thermogram (hereinafter referred to as the thermography--aided treatment group) was 67.65%, with a marked improvement rate of 26.40%; while the cure rate of the conventional acupuncture treatment group (hereinafter called the conventional treatment group) was 46.39%, the marked improvement rate being 29.90%, indicating a significant difference in therapeutic efficacy between the two groups (P less than 0.02). (2) The average duration of acupuncture therapy for the thermography aided treatment group was 6.02 weeks, whereas that for the conventional treatment group, 24 weeks. There was also a significant difference between the two groups (p less than 0.01). (3) During the entire therapeutic course, 25.2 sessions of treatment were given on the average in the thermography--aided treatment group, and 78.8 sessions in the conventional treatment group, showing a very significant difference (P less than 0.001). The present thermography--aided method exhibits advantages over the conventional one in enhancing the cure rate and shortening the duration of treatment, which is worthy to be popularized in clinical practice. It is also of certain significance in standardization and scientification of acupuncture therapy.

Zhang D; Wei Z; Wen B; Gao H; Peng Y; Wang F.

Thursday, April 28, 2016

Infrared thermography. Its role in dental research with particular reference to craniomandibular disorders.

Infrared thermography. Its role in dental research with particular reference to craniomandibular disorders. 

Biagioni PA, Longmore RB, McGimpsey JG, Lamey PJ.
 
Source
School of Clinical Dentistry, Queen's University of Belfast, UK.

Abstract
The use of infrared thermography in dentistry has been minimal, principally due to technological inadequacies of previous thermal imaging systems. However, with the ever-developing advancement in technology, current systems are capable of producing real-time, highly sensitive digitized thermal images. This development has led to an increased use of infrared imaging within both medical and dental research. The present paper describes these techniques and their previous applications within dentistry, and, through the use of a pilot study, highlights possible future applications in the assessment of craniomandibular disorders.